How to Make Agarose Gels and Run Electrophoresis
Learn how to prepare an agarose gel for DNA electrophoresis, from sealing the casting tray and mixing agarose with TAE buffer to pouring and setting the gel.
This step-by-step guide covers adding DNA stain, positioning the gel in the electrophoresis chamber, preparing samples with loading buffer, and loading DNA ladders.
You'll also learn how to connect the electrodes, run the gel, and visualize DNA bands using blue light. The tutorial includes tips for reusing agarose gels and buffer to get more out of your lab supplies.
What You'll Do
Making gel is a simple process often likened to making Jello. These gels are made with wells so a DNA solution can be suspended and segregated using the process of electrophoresis.
We start with the tray that comes with the kit. It has 2 combs.
Step: 1
Make an Enclosed Space
to Pour Hot Liquid In
Tear a piece of tape about 12’’ in length, duct tape works great.
Wrap tape around exterior of tray leaving enough extra to fold over
and stick around the bottom.
Make sure the tape is sealed tightly against the ends. Rub the tape against to prevent leakage
Step: 2
Mix the Agarose
The mixture calls for 1% Agarose Powder in TAE buffer.
This tray holds about 40 mL at the correct levels.
Correct mixture would be 40mL TAE to 0.4g Agarose powder.
Microwave at short seconds intervals with swishing in between until mix is fully dissolved. Hold the mixture up to the light to make sure all granules are completely dissolved.
Warning:
Step: 3
Pour Your Fluid
and Let Cool to Make Gel
Add 4uL of DNA Safe Gel Stain after microwaving and mix it into fluid.
Pour microwaved contents into tray with 1 or two combs resting balanced
and in position.
The fluid should reach a level shown by the diagonal line in the photo.
Place tray with fluid in fridge or leave out to air cool.
Wait until gel has fully cured before use. The gel will be slightly opaque
when cured completely.
Remove tape, then carefully remove gel from tray and place in
gel electrophoresis box with the top wells nearest to the black plug.
Step: 4
Fill Box with Buffer
and Pipette Samples
Place the gel into the electrophoresis box with the wells created by the comb nearest to the black electrodes. Some boxes don’t have colored electrodes.
Just connect the wire coming from the power supply black jack to the side
with the wells when finished loading.
Fill electrophoresis box with TAE Buffer until it slightly covers the top of the gel.
The DNA ladder will already have a loading buffer. You must mix your samples with a loading buffer so that the samples will stay in the wells.
Pipette loading buffer (6x) into your PCR reaction if you don’t need to save it
for further use. Add 9uL 6x Loading Buffer to 50uL PCR reaction or 5uL Loading Bufferto a 25uL PCR reaction. Alternatively you can pipette the loading dye onto parafilm, aluminium foil, or saran-wrap material for each sample. Keep droplets spaced apart like in the picture.
Pipette 10uL of sample onto droplet of loading buffer on the parafilm or material. Pipette up and down to mix together, then re-load pipette with mixture and transfer to a well in the gel. Repeat for all samples.
Your DNA ladder should be kept in the freezer and will need time to thaw before loading. Just warm up tubes in your hands until ready.
DO NOT MICROWAVE OR PUT IN HOT WATER.
Step: 5
Connect Electrodes to Box
and Run the Power
Connect electrodes to electrophoresis box. The black electrodes should be
on the side of the wells and the sample will move towards the red.
Check on the gel every 10 minutes and use your yellow film and blue light to identify bands. Place the yellow film in front of your eyes and shine the blue light on the gel to make the DNA fluoresce.
Cool Fact
You Can Reuse a Gel
DNA disappears into gel rendering it untraceable. You can reuse some of your buffer solution as well, but it electrolyzed, so only do this once.
Dump out half of your buffer solution and remove gel-solid.
Warning:
Break up gel into pieces small enough to fit in microwaveable vessel used in Steps 2 and 3.
Repeat Steps 2 and 3.
Place Gel back in electrophoresis box and fill with buffer until it again
covers the gel.
Warning: